An NVIDIA Xid is a driver-reported event that helps identify a GPU-related problem. It is a starting point for diagnosis, not a complete root-cause finding. Preserve the event, affected GPU identity, driver and firmware versions, workload and surrounding system logs before a reboot or reset removes useful evidence. Then follow the applicable NVIDIA guidance and the server provider’s escalation procedure.

The operational decision is whether the affected GPU or node can continue safely, should be drained from the scheduler, or needs escalation. The answer depends on the event, hardware, driver, workload and service requirements. A single event number does not establish that a GPU must be replaced.

Capture the event and its context

On Linux, NVIDIA says Xid messages are recorded in the kernel log buffer and are commonly available through the system journal or files such as /var/log/messages or /var/log/syslog, depending on the distribution. The NVIDIA Xid guide explains the log format and recommends looking for NVRM: Xid.

A read-only starting point, subject to the organization’s access policy, is:

journalctl -k --since "2026-11-20 00:00:00" | grep 'NVRM: Xid'

Replace the example time with an interval covering the incident and account for the host’s time zone and clock synchronization. Preserve preceding and following log lines, because the error line alone may not contain all context. Record the PCI bus address and GPU UUID, node name, UTC time, event text, workload or job ID and any reported process or channel. Map the PCI address to the physical slot and inventory record before making a hardware decision.

Collect the driver, CUDA and framework versions, container image or environment, GPU firmware and server BIOS versions where available. Include scheduler events, application errors, power and thermal telemetry, PCIe link information, BMC events and the state of neighboring nodes. These sources can contain sensitive hostnames, serial numbers or application details; handle and share the incident bundle according to the organization’s data policy.

Interpret the code against the right catalog

NVIDIA maintains an Xid catalog with applicability and suggested action categories for Ampere and newer devices; its documentation links to separate guidance for older GPUs. Check the exact product and driver generation rather than applying a generic internet list to every accelerator.

For example, the catalog describes Xid 13 as a general application-related exception that can have several possible causes; it also notes that software or hardware problems can occasionally surface in that form. Xid 48 concerns an uncorrectable ECC event in the catalog. Neither label alone identifies which component should be replaced. Read the current workflow, correlate the event with other evidence and involve the relevant hardware or software support team.

Avoid automatically resetting every GPU that emits an Xid. A reset or node reboot can interrupt other jobs, alter failure evidence or require dependencies to be stopped. If the applicable NVIDIA recovery guidance or site runbook calls for recovery, coordinate it with the scheduler owner, capture available diagnostics first and record the action. For suspected hardware problems, NVIDIA’s guide recommends contacting the hardware vendor; the escalation package should include the exact configuration and observed symptoms.

Establish a baseline before changing anything

Compare the affected node with its own known-good baseline and a comparable healthy node where available. Match hardware revision, driver, firmware, workload, input data and load profile before interpreting differences. Record temperatures, power, clocks, memory errors and throttling with timestamps. A GPU running hotter under a heavier job is not, by itself, evidence of defective cooling.

Keep event counts separate from incidence rates. As an illustrative calculation, if a monitoring system reports three Xid log lines from two GPUs in one day, the count is three events affecting two identified GPUs. It does not show a three-in-eight failure probability on an eight-GPU server: repeated events, different job durations and an unknown observation population make that inference invalid. A useful comparison needs the number of GPU-hours observed, the event definition and consistent collection across nodes.

For supported environments, nvidia-smi -q can provide a detailed device report, while NVIDIA Data Center GPU Manager supplies health and diagnostic capabilities. Capture tool versions and timestamps; fields and support vary by product and driver. A diagnostic failure can support escalation, but it should be interpreted with the incident evidence and vendor workflow.

Prepare a reproducible escalation package

NVIDIA documents nvidia-bug-report.sh as a driver-installed tool that collects logs and command output. It normally requires administrative privileges and can include sensitive system details. Arrange an approved collection window and review the organization’s sharing rules. The NVIDIA guide also describes a safe-mode option if collection hangs; use the instructions for the installed driver and seek support where necessary.

The incident bundle should identify the physical server and GPU UUID, exact error and time, software versions, workload configuration, preceding changes, baseline, relevant journal and BMC events, and actions already taken. Include whether the symptom follows a particular job, GPU, slot or node only when that behavior has actually been observed. Do not claim an isolated root cause from a single unsuccessful run.

If reproduction is approved, define a bounded workload, expected result, duration, stop condition and owner. Compare only configurations that differ in a controlled way. Record the result even when the problem does not recur. Stress tests, component swaps and firmware changes should follow the organization’s change and vendor procedures; they are not required first steps for every incident.

Drain, recover and return to service

An effective runbook names the on-call owner, the conditions for draining a node, who can authorize a reset, and who decides whether to escalate. Coordinate with the scheduler so no new jobs land on a node during a planned diagnostic or recovery window. Preserve the affected workload’s checkpoint or restart information where applicable.

Before returning capacity, verify the expected device inventory, telemetry and scheduler visibility. Run the agreed acceptance workload, check that error counts and service behavior meet the documented criterion, and monitor the node after reintroduction. A clean short run is useful evidence, but it does not prove that an intermittent problem can never recur.

For infrastructure planning, review the AI Server Lab catalog and share the GPU model, operating environment and service requirements through the contact form. Support availability and commercial terms depend on the actual configuration and agreement.

Sources