The practical answer: disaggregated inference assigns prompt processing and token generation to separate workers. That can let teams size the stages independently, but adds KV-cache transfer and routing complexity. It is not automatically faster: compare it with an aggregated deployment on the same model and request distribution, including time to first token, generation speed, network traffic and hardware cost.

The design question is whether better allocation of GPU resources outweighs the cost of moving intermediate state. Two accelerators serving separate stages do not automatically double useful throughput. Context length, request rate, software and topology all matter. The numerical example below is illustrative and must be replaced with measurements from the intended workload.

What each stage does

In a simplified view, prefill processes input tokens and prepares attention state. Decode generates output tokens using the KV cache. In an aggregated deployment, one worker or worker group handles both stages. In a disaggregated deployment, separate prefill and decode pools transfer the required state between them.

NVIDIA Dynamo's documentation describes the different pressures: long prompts increase prefill work, while concurrency and response length affect decode and active KV memory. This is an architectural description, not proof that separation wins on every model. For short prompts and low concurrency, transfer overhead and extra components can outweigh the benefit.

Phase separation is also distinct from KV-aware routing. They may be combined, but measuring them independently helps identify which change caused a result. Otherwise a routing change can be mistaken for an improvement attributable solely to disaggregation.

Inputs for a capacity estimate

Input Why it matters
Input and output length distributions An average can hide expensive long-context requests
Requests per second and concurrency They determine pressure on both stages and queues
Model, precision and software versions They affect memory and cache compatibility
Measured state transferred per request It determines the data moved between pools
GPU and network topology It constrains the path, latency and usable bandwidth
TTFT, generation speed and quality targets They let teams compare equivalent outcomes

Use representative, appropriately sanitised request distributions rather than one convenient prompt. If production traces are unavailable, define several explicit scenarios and see whether the decision changes with longer contexts or a higher peak rate. Label estimates as assumptions, not measured deployment results.

Worked transfer example

Assume a chosen model's measured KV transfer is 2 GB per request, and 10 requests per second complete prefill. In a simplified scenario where the full state of each request is transferred, useful data movement is 2 × 10 = 20 GB/s, or 20 × 8 = 160 Gbit/s.

The values are hypothetical, not specifications for a named model. The calculation excludes protocol overhead, bursts, retransmission, bidirectional traffic and competing services. It assumes ten states really cross the path every second. Cache reuse, another traffic distribution or a different transfer method changes the result.

A nominal 200 Gbit/s link would not guarantee 40 Gbit/s of usable headroom: line rate and application payload differ. Measure the complete path with the intended stack. Even when workers use GPUs in the same server, an unexpected transport path can make KV movement dominate latency.

Verify the transfer path

Do not assume that any two GPUs in one server exchange state over NVLink. Hardware connectivity, process placement, container isolation and the implemented backend all matter. NVIDIA provides different deployment examples and separate RDMA setup guidance; use the version and section that match the actual arrangement.

For inter-node transfers, confirm the adapters, switches, drivers and fabric configuration. For separate processes or pods on one node, check that the chosen backend actually uses the expected path. Inspect logs and counters during load. If the stack can fall back to another transport, measure that condition too: an application may still respond while missing the latency target.

Coordinate changes to a live fabric with the cluster operator, including a maintenance window and rollback plan. This capacity exercise does not replace the operating documentation for a specific system.

Compare aggregated and disaggregated runs

Run both configurations with the same model, precision, software versions, request distribution, quality target and latency objectives. Record more than average throughput: capture time-to-first-token distribution, generation latency and unsuccessful requests at several offered-load levels.

For each run, list the number of GPUs in prefill and decode, GPU memory occupancy, queue depth and network traffic. Include router resources and resilience capacity. If separation needs more GPUs to sustain the same target load, that should be visible in the comparison. Do not compare short prompts in one run with long prompts in the other and attribute the difference to architecture alone.

Question Aggregated Disaggregated
Stage placement One worker pool handles both Separate pools handle the stages
KV movement Depends on implementation An explicit transfer path needs validation
Scaling Stages are tied to the pool's allocation Pools can be evaluated separately
Additional concerns Stages can contend for resources Transport, routing and state compatibility

This is a comparison framework, not a universal performance claim. An aggregated service may still move data between GPUs, and disaggregated implementations can use different transports.

When demand changes through the day

A daily average does not replace a peak-hour workload profile. A morning burst of long documents can stress prefill even when the evening workload places more pressure on generation. Split measurements into time windows and retain the request-length distribution for each. Add a scenario in which one worker is unavailable and verify the remaining capacity of the receiving pool. Do not transfer this example to another application without measuring again: request mix and latency objectives may be very different.

Make the procurement decision

Build a worksheet for both options with target traffic, GPU allocation, measured KV transfer, latency distribution and equipment cost. Mark the values that remain assumptions. If the decision depends on an unvalidated transport or software feature, include it in a pilot before approving the bill of materials.

Explore AI server configurations or use the contact form to share the model, traffic profile and network requirements. The exact configuration, availability and delivery terms are confirmed separately for each enquiry.