On NVIDIA B200/B300 HGX and DGX systems, enabling Multi-Instance GPU (MIG) changes peer-to-peer capabilities. NVIDIA's Fabric Manager guide states that a GPU loses NVLink peer-to-peer access in MIG mode; on NVSwitch systems Fabric Manager must be running for P2P to return after MIG is disabled. NVIDIA also notes that on H100 and later systems the physical NVLink connections can remain active while MIG is enabled. An active link indicator therefore does not by itself prove application P2P access.
This matters when choosing between isolated independent jobs and one model spread across accelerators. Check the exact driver, hypervisor, guest OS and device mode; individual software stacks can add restrictions.
What MIG provides
MIG divides a supported physical GPU into instances with allocated resources. NVIDIA's supported-GPU table lists B200 with 180 GB and B300 with 288 GB, each with a maximum of seven instances. This is a maximum count, not a promise that any seven arbitrary profiles can coexist.
Check supported profile sizes and valid layouts for the exact system. Instance memory is not necessarily a simple division of nominal board capacity. Driver versions and application requirements matter too. MIG may suit independent smaller jobs when each fits in a supported profile.
For example, a service needing 35 GB plus 5 GB reserve has a preliminary 40 GB budget. These are hypothetical values, not a list of B200 or B300 profiles. Select a supported profile with sufficient headroom, then measure peak usage in the actual service.
Link state and P2P are different checks
NVIDIA's Fabric Manager guide describes MIG on A100, H100 and B200/B300. In that section NVIDIA says NVLink peer-to-peer is unavailable to the GPU in MIG mode. After MIG is disabled, P2P can be restored when the documented conditions are met; Fabric Manager must be running on NVSwitch systems.
NVIDIA separately says that GPU NVLinks can remain active during MIG on DGX H100, HGX H100 and later. Link state and the ability of particular processes to exchange device memory are therefore separate questions. Do not infer model compatibility from a green link indicator alone.
Check access in the environment where the application runs: physical host, container or virtual machine. Device exposure and policy can differ. Record the driver and documentation version because supported combinations change.
Implications for an LLM service
A model split across GPUs can require frequent intermediate transfers. Do not assume a mode intended for independent instances supports the same tensor-parallel arrangement. Ask developers which communication path the engine requires and validate that combination.
Independent smaller models may not need P2P between instances. Their criteria can instead be profile memory, latency, isolation and scheduling. Compare that deployment with a single model distributed across full GPUs as different scenarios, not as one interchangeable token-rate number.
Suppose two independent services each handle 15 requests per minute and one distributed model handles 24 at the same latency target. The two services total 30 in this hypothetical example, but the comparison is meaningful only if they solve the same task at comparable quality. These are not NVIDIA measurements.
Virtual machines add constraints
NVIDIA's vGPU for Compute guide lists additional conditions for its described NVLink P2P mode, including supported modes and platforms; the cited section does not support MIG-backed vGPU for that P2P feature. Do not generalise the limitation to every future release or form of virtualisation.
Create a compatibility matrix covering physical platform, GPU, MIG mode, hypervisor release, guest OS, driver, vGPU type and application requirements. Cross-check NVIDIA's current support matrix and the server manufacturer's documentation. Verify licensing and VM migration requirements separately.
A controlled pilot
- Save current configuration, software versions and topology.
- Agree a maintenance window and the impact of changing MIG mode on running jobs.
- Check valid profiles and application support for the installed release.
- Measure application startup and the required data path in an isolated environment.
- Record latency, memory, errors and configuration on the same workload.
- When returning to full GPUs, check Fabric Manager and actual P2P access.
Do not change modes on a production node without a drain and recovery plan. Procedures differ by GPU generation and software stack; involve the supplier if the documentation does not match the installation.
Before selecting a system
Specify whether the requirement is independent isolated services or one multi-GPU model, then give memory and latency targets. Ask for the exact HGX platform, topology, software versions, MIG limitations and a reproducible test. Explore B200 and B300 configurations or use the contact form. Availability and commercial terms require confirmation.